LAX1 (Los Angeles) El Segundo Data Center Campus

Address 200 North Nash Street, El Segundo, CA, USA Space
Open Time Power
Owner Cyxtera Air conditioning & Cooling
Contact +1 866-403-5001 ,colo.support@cyxtera.com Standards
Data Center Introduction

Cyxtera: LAX1 (Los Angeles) El Segundo Data Center Campus

Cyxtera LAX1 (Los Angeles) El Segundo Data Center Campus is located at 200 North Nash Street, El Segundo, CA, USA. The data center is 206402 sqft. There is a total of 206402 sqft in raised floor space for colocation. It has access to 34 MW of power. We found 85 data center locations within 50 miles of this facility. Certifications for this location include HIPAA, PCI-DSS, ISO 27001, NIST 800-53, SSAE-18, ISAE-3402, SSAE-16 Type 1, SOC 2 Type 2, SOC 1, SOC 2, SOC 2 Type 1, SSAE-16 Type 2, SOC 1 Type 2.

El Segundo Data Center Campus LAX1

Located just minutes from LAX, our two-story Energy Star certified Los Angeles data center provides network diverse connectivity, rigorous critical systems infrastructure and multi-tier security.

Highlights
  • Three buildings totaling 206,402 sq/ft raised floor space and access to 34MW of utility and 38.5MW of generator power
  • 3 facilities from Burbank to Irvine provide in-region site diversity ideal for deploying active/active highly available workloads
  • Customer community of 250+ media companies, XaaS providers, content providers and other large enterprises
  • Compliance with SSAE18 SOC-1, SOC-2, ISO 27001, PCI DSS, and NIST standards
  • HIPAA aligned
  • Connectivity to 12 unique network service providers and growing community of service providers
  • Solution deployment options include individual Secure Cabinets and dedicated Secure Cages
  • Native connection into AWS and Google Cloud Interconnect through Metro Connect

Amenities

  • Free secure Wi-Fi
  • Break room
  • Food and beverage vending machines
  • Crash carts and loaner tools
  • Work kiosks
  • Conference room
Technical Specifications

Utility Power 8.0 MW

UPS Capacity 2.7 MW

UPS Configuration N+1

Generator Capacity 6.25 MW

Generator Configuration N+1

Fuel Capacity 15,000 Gal.

Cooling Configuration N+1

Cooling Capacity 1010 Tons

Carriers

AT&T
CenturyLink
Cogent
Level 3
Time Warner Cable
Verizon
XO
Zayo 






Fire Protection
VESDA provides early warning detection, Pre-action dry pipe sprinkler system
Support Services
Gold Support (remote hands), Structured Cabling, Secure on-site spare and tool storage, Office space